Home > ELECTRICAL > ROUGH ELECTRICAL > SAFETY & DISCONNECT SWITCHES > AC DISCONNECT SWITCHES > 60 AMP
Sort By:
1
Eaton DPU222RP Type ACD Non-Fusible Pullout Disconnect Switch GE Electrical TFN60RCP AC Disconnect Switches Square D QO200TRCP Molded Non-Fusible Disconnect Switch
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance. Steel enclosure. 2-pole, 3-wire, 240 VAC, rated 10 hp. For central air conditioner. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 4-3/4 x 7-1/2 x 2 in. UL1429 enclosure pullout switch, UL listed. Air conditioning disconnects from Schneider Electric are Underwriters Laboratories? (UL?) Listed NEMA Type 3R rainproof. They are designed to meet all current National Electrical Code? (NEC?) requirements for a disconnecting means on residential and commercial air conditioning installations, as well as other single-phase applications, such as swimming pools and pump houses.
Cutler-Hammer DPF222RP AC Disconnect Switches Cutler-Hammer AC222URNMP-A2 AC Disconnect Switches GE Electrical TF60RCP AC Disconnect Switches
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance. Single phase, 2 pole, 2 wire, 240 VAC. Rated 3 hp at 120 V, 10 hp at 240 V. For top and bottom entry and exit, with provision for type H conduit hub. Heavy-duty, high strength, rugged polymer enclosure with UV-resistant features. Swing-up cover remains in place when in open position, protective shield can be removed for access to fuses. No GB4 ground bar and No 360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5 in x 8-5/8 in x 3-1/2 in. UL listed file No E5239. Steel enclosure. 2-pole, 3-wire, 120/240 VAC, rated 10 hp. Uses cartridge fuses. For central air conditioner. Designed to comply with code requirements for disconnecting means within sight of central air conditioners and heat pumps. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 6-1/2 x 9 x 3-1/4 in. UL869 service equipment, UL listed.
GE Electrical TPN60R1 AC Disconnect Switches Siemens Energy WN2060U AC Disconnect Switches Eaton DPB222RP Type ACD Molded Non-Automatic Breaker Disconnect Switch
Suitable for use as service entrance equipment. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. Designed to comply with code requirements for disconnecting central air conditioners and heat pumps. Open sides and top for quick installation. Impact and corrosion-resistant GE Noryl thermoplastic resin. 2-pole, 3-wire, 120/240 VAC, rated 10 hp. 5-3/4 in x 8 in x 3-1/8 in. UL1429 enclosed pullout switch, UL Listed. Single phase, 2 pole, 2 wire, 240 V, rated 10 HP, steel enclosure. All lugs positioned for bottom entry and exit wiring. Easy mounting for quick installation. Pullout head can be replaced in off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. 5-5/32 in x 7-5/16 in x 2-7/32 in. UL listed. Air conditioning disconnect, molded case switch looks like a circuit breaker but operates like an ordinary household light switch. 60 A, 2-pole, 240 VAC. Metallic, galvanized steel enclosure, NEMA 3R, rainproof. Packaged for retail sale. Wire size range Cu or Al at 60 or 70 deg C, #14-3. UL listed, CSA approved.
   
 
1