Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE
Choose a sub category:
BUILDING WIRE / NM BUILDING WIRE / THHN BUILDING WIRE / UF
ENTRANCE CABLE ARMORED CABLE GROUND WIRE
LAMP CORD SJ CORD SPECIALTY WIRE
Sort By:
1 2
Southwire 14YEL-SOLX500 Building Wire Southwire 10BLU-SOLX500 Solid Single Building Wire Barogation 547050408 Sprinkler Cable
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire Sprinkler Wire, 18 AWG Wire, 250 ft Length, 5 Conductors, Polyethylene Conductor Insulation, Stranded, 0.246 in Sheath Diameter, 24 V, -20 to 75 deg C Operating
Quantum TPE 16/3 SJEOOW 250' SJEOOW Electrical Cord Southwire SEU Service Entrance Cable Southwire SER Service Entrance Cable
Provides premium oil resistance, water resistance and flexibility. Use in wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites. Approved for outdoor use. May be completely immersed in water. Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential. Extra flexible copper conductors. Rated at -60 to 105 deg. 13 A - 300 V - 250 ft coil. Meets all applicable requirements of: ASTM, UL 62 and CSA Standard 22.2 No 49. OSHA acceptable. C-UL, UL and MSHA listed. All sizes meet CSA FT-2. Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 deg C in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944 and NEC requirements. Used as a panel feed in multiple unit dwellings. May be used in wet or dry locations at temperatures not to exceed 90 deg C. 600 V maximum. Meets or exceeds UL Standard 44 for type XHHW-2 conductors or UL Standard 83 for THHN/THWN conductors, UL Standard 854, Federal Specification A-A59544, NEC requirements.
Romex SIMpull 6/2UF-W/GX500 Type UF-B Building Wire Southwire SEU Service Entrance Cable Southwire SEU Service Entrance Cable Wire
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 deg C in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944 and NEC requirements. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 deg C for dry locations or 75 deg C for wet locations, 600 V. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight- and moisture-resistant, flame retardant jacket. UL listed. Amp capacities listed are at 30 deg C/85 deg F.
Southwire 55039401 Power Supply Cord Quantum TPE 55044903 SEOOW Power Cord Zenith AS110024C Speaker Wire
Southwire Power Cord, Portable, 10 AWG Wire, 250 ft Length, 4 Conductors, Strands per Conductor: 104, 104/30 Strand, Copper Conductor, TPE Conductor Insulation, Stranded, TPE Sheath, Black Sheath, SEOOW Shielding, 600 V, 25 A, -50 to 105 deg C Operating Wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites. 8 ga, 3 conductor stranded with insulated ground. Rated -50 to 105 deg C. 40 A, 600 V. RoHS compliant. The Zenith 24 ga Speaker Wire, 100 ft provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity.
Zenith AS105016C Speaker Wire Zenith AS105018C Speaker Wire Zenith AS110018C Speaker Wire
The Zenith 16 ga speaker wire provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity. The Zenith 18 ga speaker wire provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity. The Zenith 18 ga speaker wire provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity.
WIRE THERM CL-2 18/2 BRN 100FT Romex SIMpull 14/2NM-WGX25 Building Wire Duraclad 55274921 Type MC Armored Cable
Southwire SIMpull Thermostat Wire, Type CL-2, 18 AWG Wire, 100 ft Length, 2 Conductors, Copper Conductor, Plastic Conductor Insulation, Solid, PVC Sheath, Brown Sheath, 150 V, Moisture, Sunlight Resistance, -20 to 60 deg C Operating Romex Building Wire, NM-B, 14 AWG Wire, 25 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Nylon Sheath, White Sheath, 600 V, 15 A, 90 deg C Operating Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Duraclad 55278321 Type MC Armored Cable Armorlite 68579221 Type MC Armored Cable Zenith AS105014C Speaker Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. The Zenith 14 ga speaker wire, 50 ft provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity.
Romex SIMpull 12/2NM-WGX25 Building Wire Armorlite 68580021 Type MC Armored Cable Southwire 22973236 THHN Building Wire
Romex Building Wire, NM-B, 12 AWG Wire, 25 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Nylon Sheath, Yellow Sheath, 600 V, 20 A, 90 deg C Operating Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 22974036 THHN Building Wire Southwire 22975736 THHN Building Wire Southwire 22977336 THHN Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Romex SIMpull 14/2NM-WGX50 Building Wire Romex SIMpull 14/2UF-W/GX25 Building Wire Duraclad 55278521 Type MC Armored Cable
Romex Building Wire, NM-B, Wire Size: 14 AWG, 50 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Sheath Material: Nylon, Sheath Color: White, 600 V, 15 A, Operating Temperature: 90 deg C Southwire Feeder Cable with Ground, Underground, 14 AWG Wire, 25 ft Length, 2 Conductors, Copper Conductor, PVC Sheath, Gray Sheath, 600 V, 90 deg C Operating Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Duraclad 55275021 Type MC Armored Cable Duraclad 55278322 Type MC Armored Cable Romex SIMpull 14/3NM-WGX25 Building Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Romex Building Wire, NM-B, THHN, Wire Size: 14 AWG, 25 ft L, Number of Conductors: 3, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Pink, 600 V, 15 A, Operating Temperature: 90 deg C, Includes: Ground Wire
Romex SIMpull 12/2NM-WGX50 Building Wire Romex SIMpull 14/2UF-WGX50 Building Wire Armorlite 68579222 Type MC Armored Cable
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Romex Building Wire, UF-B, Wire Size: 14 AWG, 50 ft L, Number of Conductors: 2, Strands per Conductor: 2, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Gray, 600 V, 15 A, Operating Temperature: 90 deg C Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed.
Southwire 22964152 THHN Building Wire Duraclad 55274922 Type MC Armored Cable Romex SIMpull 12/2UF-W/GX25 Building Wire
Southwire Building Wire, THHN, Wire Size: 12 AWG, 100 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Black, Sheath Diameter: 0.13 in, 600 VAC, 20 A, Operating Temperature: 194 deg F Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
SIMpull 22964151 THHN Building Wire SIMpull 22965851 THHN Building Wire SIMpull 22966651 THHN Building Wire
Southwire Building Wire, THHN, Wire Size: 12 AWG, 50 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Black, Sheath Diameter: 0.13 in, 600 VAC, 20 A, Operating Temperature: 194 deg F Southwire Building Wire, THHN, Wire Size: 12 AWG, 50 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: White, Sheath Diameter: 0.13 in, 600 VAC, 20 A, Operating Temperature: 194 deg F Southwire Building Wire, THHN, Wire Size: 12 AWG, 50 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Red, Sheath Diameter: 0.13 in, 600 VAC, 20 A, Operating Temperature: 194 deg F
SIMpull 22968251 THHN Building Wire Armolite 68580022 Solid Metal Clad Cable Romex SIMpull 14/3NM-WGX50 Building Wire
Southwire Building Wire, THHN, Wire Size: 12 AWG, 50 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Green, Sheath Diameter: 0.13 in, 600 VAC, 20 A, Operating Temperature: 194 deg F Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Romex Building Wire, NM-B, 14 AWG Wire, 50 ft Length, 3 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, White Sheath, 19 mil Sheath Diameter, 600 V, 15 A, 90 deg C Operating, Includes: Ground Wire
Armorlite 68583421 Type MC Armored Cable Romex SIMpull 12/2UF-WGX50 Building Wire Romex SIMpull 14/2UF-WGX100 Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Southwire? copper UF-B cable is generally used as feeder to outside post lamps, pumps and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 V.
Romex SIMpull 14/2NM-WGX100 Building Wire Romex SIMpull 12/3NM-WGX25 Building Wire Southwire 22973237 THHN Building Wire
Romex Building Wire, NM-B, THHN, 14 AWG Wire, 100 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, White Sheath, 19 mil Sheath Diameter, 600 V, 15 A, 90 deg C Operating, Includes: Ground Wire Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 22977337 THHN Building Wire Southwire 22974037 THHN Building Wire Southwire 22975737 THHN Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Duraclad 55278323 Type MC Armored Cable Romex SIMpull 10/2NM-WGX25 Building Wire Romex SIMpull 12/2NM-WGX100 Building Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Romex Building Wire, NM-B, THHN, 12 AWG Wire, 100 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, Yellow Sheath, 600 V, 20 A, 90 deg C Operating
Romex SIMpull 14/2NM-WGX250 Building Wire Romex SIMpull 10/2UF-W/GX25 Type UF-B Building Wire Duraclad 55274923 Type MC Armored Cable
Romex Building Wire, NM-B, THHN, 14 AWG Wire, 250 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, White Sheath, 600 V, 15 A, 90 deg C Operating Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Romex SIMpull 14/3NM-WGX100 Building Wire Romex SIMpull 10/3NM-WGX25 Building Wire Romex SIMpull 12/3UF-WGX50 Type UF-B Building Wire
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Armolite 68580023 Solid Metal Clad Cable Romex SIMpull 12/3NM-WGX50 Building Wire WIRE BUILDING 8/3NM-B W/G 25FT
Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C.
Armolite 68583422 Solid Metal Clad Cable Romex SIMpull 12/3UF-WGX100 Type UF-B Building Wire Romex SIMpull 14/2UF-W/GX250 Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Romex SIMpull 12/2UF-WGX100 Building Wire WIRE BUILDING 6/3NM-B W/G 25FT Romex SIMpull 12/2NM-WGX250 Building Wire
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C. Romex Building Wire, NM-B, 12 AWG Wire, 250 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, Yellow Sheath, 600 V, 20 A, 90 deg C Operating
Romex SIMpull 10/2UF-WGX50 Building Wire Romex SIMpull 10/2NM-WGX50 Building Wire Romex SIMpull 12/3NM-WGX100 Type NM-B Building Wire
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Romex Sheathed Cable, NM-B, Wire Size: 12 AWG, 100 ft L, Number of Conductors: 3, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Purple, 600 V, 20 A, Operating Temperature: 90 deg C
Romex SIMpull 14/3NM-WGX250 Building Wire Romex SIMpull 10/3UF-WGX50 Type UF-B Building Wire Romex SIMpull 10/3NM-WGX50 Building Wire
Romex Building Wire, NM-B, THHN, 14 AWG Wire, 250 ft Length, 3 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, White Sheath, 19 mil Sheath Diameter, 600 V, 15 A, 90 deg C Operating, Includes: Ground Wire Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Romex Building Wire, NM-B, 10 AWG Wire, 50 ft Length, 3 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, Orange Sheath, 600 V, 30 A, 90 deg C Operating
Romex SIMpull 10/2NM-WGX100 Type NM-B Building Wire Armolite 68583423 Solid Metal Clad Cable WIRE BUILDING 8/3NM-B W/G 50FT
Romex Building Wire, NM-B, THHN, Wire Size: #10 AWG, 100 ft L, Number of Conductors: 2, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Orange, Sheath Diameter: 24 mil, 600 V, 30 A, Operating Temperature: 90 deg C, Includes: Ground Wire Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C.
Romex SIMpull 10/2UF-WGX100 Type UF-B Building Wire Romex SIMpull 12/2UF-W/GX250 Building Wire Duraclad 55278301 Type MC Armored Cable
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
WIRE BUILDING 6/3NM-B W/G 50FT Romex SIMpull 14/3UF-WGX250 Type UF-B Building Wire Romex SIMpull 10/3UF-W/GX100 Type UF-B Building Wire
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Armorlite 68580001 Type MC Armored Cable Romex SIMpull 10/3NM-WGX100 Type NM-B Building Wire Romex SIMpull 12/3NM-WGX250 Type NM-B Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
   
 
1 2