|
|
|
|
|
|
|
|
|
|
|
Type L pellent vent storm collar used at the top of the flashing to assist in shedding water from the assembly.
|
Selkirk Tee Support, Dimensions: 3 in Dia
|
Selkirk Trim Plate, Black, Dimensions: 3 in Dia
|
|
|
|
|
|
|
|
|
|
|
|
|
For use on the exterior to support pipe to wall. Use only with Selkirk pellet stove pipe. Hold pipe 3 in from wall. UL listed.
|
Vertical round top/termination cap. Type L pellet vent. Cap provides necessary protection of the vent system from rain and other elements. UL listed.
|
Type L pellet vent. Flashings are used for keeping water and other debris from entering between the pipe and roof. Adjustable pitch. UL Listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
Adjustable pipe connector will connect to 3 in appliance outlet and is securely fastened with a hose clamp, while the male end adapts to the standard inlet end of 3 in VP pipe, elbow or tee. UL listed.
|
Exit cone cap is designed to direct flue gases perpendicular to the wall and to increase their velocity, projecting them further away from the building. UL listed.
|
Type L vent systems for pellet stove applications. For use in accommodating unusual offsets and configurations. Up to 90 deg maximum. Rated for flue temperatures up to 570 deg F. Model VP may be installed with a minimum 1 in air space clearance to combustible surfaces, framing lumber, drywall and plywood. UL listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
Type L pellet vent ceiling support/firestop.
|
Horizontal termination cap is designed specifically for use on installations in which the Type L vent terminates in a horizontal orientation on the outside of a structure. UL listed.
|
Type L Pellet Vent to Selkirk Insulated Chimney Adapters are for use in connecting a Model VP Vent System into an existing Selkirk Chimney system.
|
|
|
|
|
|
|
|
|
|
|
|
|
Type L pellet vent wall thimble must be used in all thru-the-wall installations involving combustible construction. UL listed.
|
Type L vent systems for pellet stove applications. For use in accommodating unusual offsets and configurations. Up to 90 deg maximum. Rated for flue temperatures up to 570 deg F. Model VP may be installed with a minimum 1 in air space clearance to combustible surfaces, framing lumber, drywall and plywood. UL listed.
|
Type L Pellet Vent to Selkirk insulated chimney adapters are for use in connecting a Model VP vent system into an existing Selkirk chimney system.
|
|
|
|
|
|
|
|
|
|
|
|
|
Type L air insulated pellet vent tee with cap designed for use in changing the orientation of the vent from horizontal to vertical and making inspection and cleaning of pellet stove system easier. UL listed.
|
For pellet and corn appliances. Kit contains 3 in horizontal cap, 3 in 90 deg elbow, 3 in wall bracket, five 3 in 1 ft pipe lengths, 3 in tee with cleanout, 3 in wall thimble and 3 in pipe connector. System rated for flue temperatures up to 570 deg. Proven coupling joint connects in seconds to assure joint integrity. Gasketed joint design. Inner wall is 304 stainless steel, outer wall is paintable galvanized. Rolled-over male end eliminates sharp edges. 1 in clearance to combustibles. Removable tee cap for inspection and cleaning. Internal spacing bead assures uniform insulating air space between pipe walls. Meets UL-641 and UL-103.
|
For pellet and corn appliances. Kit contains 4 in horizontal cap, 4 in 90 deg elbow, 4 in wall bracket, five 4 in 1 ft pipe lengths, 4 in tee with cleanout, 4 in wall thimble, 4 in tee support, 3 to 4 in pellet increaser, 4 in pipe connector and 3 in pipe connector. System rated for flue temperatures up to 570 deg. Proven coupling joint connects in seconds to assure joint integrity. Gasketed joint design. Inner wall is 304 stainless steel, outer wall is paintable galvanized. Rolled-over male end eliminates sharp edges. 1 in clearance to combustibles. Removable tee cap for inspection and cleaning. Internal spacing bead assures uniform insulating air space between pipe walls. Meets UL-641 and UL-103.
|
|